文章摘要
张昌凡,罗利祥,何静,张淼滢,周飞,廖慧君.匝间短路故障对永磁同步电机失磁影响的分析与研究[J].包装工程,2015,36(15):124-129.
ZHANG Chang-fan,LUO Li-xiang,HE Jing,ZHANG Miao-ying,ZHOU Fei,LIAO Hui-jun.Effects of Inter-turn Short-circuit Fault on Demagnetization of Permanent Magnet Synchronous Machines[J].Packaging Engineering,2015,36(15):124-129.
匝间短路故障对永磁同步电机失磁影响的分析与研究
Effects of Inter-turn Short-circuit Fault on Demagnetization of Permanent Magnet Synchronous Machines
投稿时间:2014-10-26  修订日期:2015-08-10
DOI:
中文关键词: 有限元法  短路故障  永磁同步电机  失磁
英文关键词: finite element methods  short circuit fault  permanent-magnet synchronous motor  demagnetization
基金项目:国家自然科学基金 (61273157, 6147311); 湖南省自然科学基金 (14JJ5024, 2015JJ5011)
作者单位
张昌凡 湖南工业大学株洲 412007 
罗利祥 湖南工业大学株洲 412007 
何静 1. 湖南工业大学株洲 4120072. 国防科技大学长沙 410073 
张淼滢 湖南工业大学株洲 412007 
周飞 南通大学南通 226019 
廖慧君 湖南工业大学株洲 412007 
摘要点击次数:
全文下载次数:
中文摘要:
      目的 研究不同相带第1匝发生短路故障对永磁电机失磁的影响。方法 利用有限元法, 在对电机的设计参数及绕组结构进行介绍的基础上, 运用ansoft软件建立了永磁电机模型, 并计算了不同故障类型对永磁电机的失磁影响; 提取了不同故障下, 永磁电机短路线圈的电流变化波形和磁密矢量分布图; 从绕组分布的2个不同方面,讨论了不同相带的第1匝发生短路故障时, 去磁磁场的大小、 失磁区域的大小和失磁区域分布之间的关系。结果 失磁区域的大小和分布与短路线圈的空间位置有关。结论 该研究结果可以作为判断短路线圈与永磁体失磁位置的依据, 也为永磁同步电机的设计提供了技术参考。
英文摘要:
      This study aimed to analyze the permanent magnets of PMSM demagnetized by first turn of the different phase belt short circuit fault. Firstly, parameters and coil structure of the designed machines were introduced. Secondly, the Finite Element model of PMSM was established with the ansoft software, which was used to simulate the permanent magnets of PMSM demagnetized by different fault types. Thirdly, current curves of short circuited coils and motor flux density vector of permanent-magnet motor were extracted under different faults. From two different aspects of the distribution of the winding, the relationship among the size of the demagnetization magnetic field, the size of the demagnetization area and the distribution of the demagnetization area were studied when first turn of the different phase belt short circuit faults occur. Our results proved that the demagnetization area and the distribution of the demagnetization area are related to the spatial position of the short circuit coils. Taken together, our findings not only can be used as the basis for judging short circuited coils and location of the demagnetization area, but also provide the technical reference for the design of permanent magnet synchronous motor.
查看全文   查看/发表评论  下载PDF阅读器
关闭

关于我们 | 联系我们 | 投诉建议 | 隐私保护 | 用户协议

您是第20793919位访问者    渝ICP备15012534号-2

版权所有:《包装工程》编辑部 2014 All Rights Reserved

邮编:400039 电话:023-68795652 Email: designartj@126.com

    