王洪波,赵乐,郭军伟,朱先约,殷延齐,谢玉龙,刘惠民.固相萃取净化-连续流动法测定纸质品中Cr(Ⅵ)[J].包装工程,2016,37(1):107-110,163. WANG Hong-bo,ZHAO Le,GUO Jun-wei,ZHU Xian-yue,YIN Yan-qi,XIE Yu-long,LIU Hui-min.Determination of Cr(VI) Residues in Paper-made Packaging by Continuous Flow Method after Solid Phase Extraction Cleanup[J].Packaging Engineering,2016,37(1):107-110,163. |
固相萃取净化-连续流动法测定纸质品中Cr(Ⅵ) |
Determination of Cr(VI) Residues in Paper-made Packaging by Continuous Flow Method after Solid Phase Extraction Cleanup |
投稿时间:2015-05-07 修订日期:2016-01-10 |
DOI: |
中文关键词: 六价铬 固相萃取净化 纸质品 连续流动法 |
英文关键词:Cr(VI) solid phase extraction cleanup paper-made packaging continuous flow method |
基金项目: |
作者 | 单位 |
王洪波 | 中国烟草总公司郑州烟草研究院,郑州 450001 |
赵乐 | 中国烟草总公司郑州烟草研究院,郑州 450001 |
郭军伟 | 中国烟草总公司郑州烟草研究院,郑州 450001 |
朱先约 | 甘肃烟草工业有限责任公司技术研发中心,兰州 730050 |
殷延齐 | 江苏中烟工业有限责任公司徐州卷烟厂,徐州 221000 |
谢玉龙 | 甘肃烟草工业有限责任公司技术研发中心,兰州 730050 |
刘惠民 | 中国烟草总公司郑州烟草研究院,郑州 450001 |
|
Author | Institution |
WANG Hong-bo | Zhengzhou Tobacco Institute of CNTC, Zhengzhou 450001, China |
ZHAO Le | Zhengzhou Tobacco Institute of CNTC, Zhengzhou 450001, China |
GUO Jun-wei | Zhengzhou Tobacco Institute of CNTC, Zhengzhou 450001, China |
ZHU Xian-yue | Technic R & D Center of Gansu Tobacco Industry Co., Ltd., Lanzhou 730050, China |
YIN Yan-qi | Xuzhou Cigarette Factory China Tobacco Jiangsu Industrial Co., Ltd., Xuzhou 221000, China |
XIE Yu-long | Technic R & D Center of Gansu Tobacco Industry Co., Ltd., Lanzhou 730050, China |
LIU Hui-min | Zhengzhou Tobacco Institute of CNTC, Zhengzhou 450001, China |
|
摘要点击次数: |
全文下载次数: |
中文摘要: |
目的 建立一种固相萃取净化-连续流动法测定纸质品中六价铬残留量的方法。方法 针对样品中的六价铬, 用pH为8.0的磷酸二氢钾缓冲溶液振荡萃取30 min, 经聚酰胺SPE柱净化, 然后用连续流动分析仪进行了六价铬的测定。结果 文中方法的检出限为0.044 mg/kg, 回收率在84.0%~99.0%之间, 相对标准偏差小于8.60%。结论 建立的方法具有操作简便、 快速、 灵敏度高等优点, 适用于纸质品中六价铬残留量的快速测定。 |
英文摘要: |
The aim of this study was to develop a method for the determination of Cr(VI) residues in paper-made packaging by continuous flow method after solid phase extraction cleanup. Cr(VI) was extracted from the sample by oscillation using the solution of potassium hydrogen phosphate (pH=8.0), cleaned up by solid phase extraction of polyamide, and then determined by continuous flow method. The detection limit of Cr(VI) in the method was 0.044 mg/kg, the recovery was in the range of 84.0%~99.0%, and the relative standard deviation (RSD) was less than 8.60%. The real sample analysis showed that this simple, fast and accurate method could be used for the determination of the residues of Cr(VI) in paper-made packaging samples. |
查看全文 查看/发表评论 下载PDF阅读器 |
关闭 |