文章摘要
任小军,尤文斌,周优良,牛跃听.抗高过载防护结构的设计与性能测试[J].包装工程,2017,38(11):64-68.
REN Xiao-jun,YOU Wen-bin,ZHOU You-liang,NIU Yue-ting.Design and Performance Test of Anti-high-overload Protective Structure[J].Packaging Engineering,2017,38(11):64-68.
抗高过载防护结构的设计与性能测试
Design and Performance Test of Anti-high-overload Protective Structure
投稿时间:2016-11-17  修订日期:2017-06-10
DOI:
中文关键词: 新型防护结构  高过载冲击  马歇特锤试验  加速度
英文关键词: new protective structure  high overload impact  Marshall hammer experiment  acceleration
基金项目:国家自然科学基金(61471385)
作者单位
任小军 中北大学 电子测试技术国家重点实验室太原 030051 
尤文斌 中北大学 电子测试技术国家重点实验室太原 030051 
周优良 中北大学 电子测试技术国家重点实验室太原 030051 
牛跃听 中国人民解放军军械工程学院石家庄 050000 
摘要点击次数:
全文下载次数:
中文摘要:
      目的 弹载记录仪在回收过程中,存在记录仪因硬着陆产生的高冲击力和高过载加速度使仪器损毁而致有效数据失效的现象。针对该问题设计新型双层壳体两级缓冲隔离的电路防护结构,并进行性能测试。方法 结合Ansys/Workbench有限元数值模拟软件仿真分析该结构在冲击过程中的形变和受冲击过载特性,同时使用马歇特锤对使用该防护结构的记录仪模拟高冲击、高过载环境实验,由记录仪存储双层防护壳体内外嵌入的加速度传感器信号,并对多次试验信号数据进行处理和分析。结果 在过载加速度小于25 000g时,该多层防护结构具有良好的缓冲效果,对记录仪保护效果良好;各层材料的声阻抗差别会影响整体保护效果,差别越大效果越好。结论 该防护结构在高过载冲击环境下能有效衰减冲击效应,保护电子设备的安全。
英文摘要:
      The work aims to design a new type of double-layer buffer-isolation circuit protective structure and conduct performance test, with respect to the problem that the valid data fails because the recorder is damaged by the high impact and high overload acceleration due to hard landing in the recovery process of missile-borne recorder. The deformation and overload characteristics of the structure in the impact process were simulated and analyzed in combination with Ansys/Workbench finite element numerical simulation software, and the Marshall hammer was adopted to simulate the high impact and high overload environment experiments on the recorder with the protective structure. The recorder stored the signals of acceleration sensors embedded inside and outside the double-layer protection enclosure. Then, the data from multiple tests were processed and analyzed. When the overload acceleration was less than 25 000g, the multilayer protective structure had good cushioning effect and could properly protect the recorder; and the acoustic impedance difference of each layer of materials would affect the overall protection effect. The greater the difference was, the better the effect was. The protective structure can effectively reduce the impact effect to protect the electronic equipment in the high overload impact environment.