文章摘要
成涛,胡奇,刘阚,侯世聪,刘曙光,赵乐,王洪波.基于ICP-MS法的包装用水基型胶粘剂中硼酸/硼砂残留量的快速检测[J].包装工程,2020,41(7):120-124.
CHENG Tao,HU Qi,LIU Kan,HOU Shi-cong,LIU Shu-guang,ZHAO Le,WANG Hong-bo.Rapid Determination of Boric Acid or Borax Residual in Water-based Adhesive for Packaging Using ICP-MS[J].Packaging Engineering,2020,41(7):120-124.
基于ICP-MS法的包装用水基型胶粘剂中硼酸/硼砂残留量的快速检测
Rapid Determination of Boric Acid or Borax Residual in Water-based Adhesive for Packaging Using ICP-MS
投稿时间:2019-09-24  修订日期:2020-04-10
DOI:10.19554/j.cnki.1001-3563.2020.07.016
中文关键词: 硼酸/硼砂  包装用水基胶粘剂  ICP-MS  涡旋萃取
英文关键词: boric acid or borax  water-based adhesive for packaging  ICP-MS  vortex oscillation extraction
基金项目:
作者单位
成涛 1.江苏中烟工业有限责任公司南京卷烟厂南京 210012 
胡奇 1.江苏中烟工业有限责任公司南京卷烟厂南京 210012 
刘阚 1.江苏中烟工业有限责任公司南京卷烟厂南京 210012 
侯世聪 1.江苏中烟工业有限责任公司南京卷烟厂南京 210012 
刘曙光 1.江苏中烟工业有限责任公司南京卷烟厂南京 210012 
赵乐 2.中国烟草总公司郑州烟草研究院郑州 450001 
王洪波 2.中国烟草总公司郑州烟草研究院郑州 450001 
摘要点击次数:
全文下载次数:
中文摘要:
      目的 为保证包装用水基型胶粘剂产品质量安全,研究建立一种包装用水基型胶粘剂中硼酸/硼砂的ICP-MS快速测定方法。方法 样品用稀硝酸溶液涡旋震荡,使水基型胶粘剂完全分散破乳,取上层溶液经高速离心后用ICP-MS进行测定,优化了萃取硝酸溶液浓度和涡旋震荡萃取时间。结果 获得的最佳萃取硝酸溶液体积分数为15%,涡旋震荡萃取时间为20 min。方法的检出限为9.43 μg/kg,样品加标回收率为97.0%~103.0%,相对标准偏差小于3.0%(n=6)。结论 建立的方法操作简便快速,灵敏度高,结果准确可靠,可适合于包装用水基型胶粘剂中硼酸/硼砂含量的快速测定;实际检测样品中有少量硼酸/硼砂残留,但均符合GB 9685规定的最大迁移限量(6 mg/kg)的要求。
英文摘要:
      The paper aims to develop an analytical method inductively coupled plasma (ICP-MS) for rapid determin-ing boric acid or borax in water-based adhesive to guarantee the quality of water-based adhesives for packaging. The wa-ter-based adhesives were completely dispersed and demulsified with nitric acid solution by the vortex oscillation. The solution was centrifuged at high speed and determined by ICP-MS, and the concentration of extracting nitric acid solution and the extracting time of vortex oscillation were optimized. The optimum concentration of nitric acid solution was 15% (volume fraction) and the extraction time of vortex oscillation was 20 minutes. The results showed that the detection limit of boron acid was 9.43 μg/kg. The recoveries were in the range of 97.0% to 103.0% and the relative standard deviation was 3.0% (n=6). This method is simple, rapid and accurate, and suitable for rapid determination of boric acid or borax in water-based adhesive for packaging. A small amount of boric acid/borax residual is found in the actual samples, but they all meet the requirement of specific migration limit of 6 mg/kg in GB 9685.