文章摘要
王洁,刘健,刘善慧,苏舟,林晓婷,侯和平,许小静.卫星式柔印机中心压印滚筒螺旋流道冷却性能研究[J].包装工程,2024,45(7):205-213.
WANG Jie,LIU Jian,LIU Shanhui,SU Zhou,LIN Xiaoting,HOU Heping,XU Xiaojing.Cooling Performance of Spiral Channels in Central Impression Cylinder of Satellite Flexographic Press[J].Packaging Engineering,2024,45(7):205-213.
卫星式柔印机中心压印滚筒螺旋流道冷却性能研究
Cooling Performance of Spiral Channels in Central Impression Cylinder of Satellite Flexographic Press
投稿时间:2023-10-27  
DOI:10.19554/j.cnki.1001-3563.2024.07.026
中文关键词: 中心压印滚筒  冷却水流道  数值模拟  温度场  轴向温差
英文关键词: central impression cylinder  cooling channel  numerical simulation  temperature field  axial temperature difference
基金项目:陕西省自然科学基础研究计划(2022JM-236);西安航天华阳机电装备有限公司技术服务项目(HYZB-Z-23-122)
作者单位
王洁 西安理工大学 印刷包装与数字媒体学院西安 710054 
刘健 西安理工大学 印刷包装与数字媒体学院西安 710054 
刘善慧 西安理工大学 印刷包装与数字媒体学院西安 710054 
苏舟 西安理工大学 印刷包装与数字媒体学院西安 710054 
林晓婷 西安理工大学 印刷包装与数字媒体学院西安 710054 
侯和平 西安理工大学 印刷包装与数字媒体学院西安 710054 
许小静 西安航天华阳机电装备有限公司西安 710100 
摘要点击次数:
全文下载次数:
中文摘要:
      目的 探究卫星式柔印机在印刷过程中,中心压印滚筒内部冷却水流道结构对其冷却效果的影响。方法 以双层中心压印滚筒为研究对象,采用数值模拟方法分析螺旋流道内冷却水的速度场和外滚筒的温度场,并与无螺旋流道的中心压印滚筒进行对比;探究流道截面形状对滚筒表面轴向温差的影响规律。结果 有螺旋流道的滚筒的表面温度整体较低,且轴向温差(4.2 ℃)更小。在相同的入口流速条件下,横截面高宽比大的螺旋流道滚筒表面轴向温差更小。在入口冷却水流速为2.5 m/s的条件下,横截面高宽比为0.6的螺旋流道对应的滚筒表面轴向温差为2.46 ℃。结论 采用高宽比较大的矩形截面螺旋流道,有利于缩小中心压印滚筒表面的轴向温差,从而改善滚筒的冷却效果。
英文摘要:
      The work aims to investigate the cooling effect of the spiral flow channel in a central impression cylinder of satellite flexographic press during printing process. With double-walled central impression cylinder as the research object, the velocity field and temperature field of cooling water within the channels, and the temperature field of the outer wall of the impression cylinder were analyzed through numerical simulation. The simulated results were compared with those of a double-walled cylinder without spiral flow channels. The effect of rectangular cross-sectional geometries of the spiral flow channel on the axial temperature difference of the cylinder surface was discussed. The cylinder with the spiral flow channel had a lower surface temperature and a smaller temperature difference of 4.2 °C. The spiral flow channel with a greater height/width ratio in cross-sectional dimensions contributed to a smaller axial temperature difference at the same inlet flow velocity. When the inlet flow velocity of the cooling water was 2.5 m/s, and cross-section height/width ratio of the flow channel was 0.6, the axial temperature difference on the surface of the cylinder was 2.46 °C. The rectangular spiral flow channels with a greater cross-section height/width ratio are beneficial to reducing the surface temperature difference of the central impression cylinder, having a better cooling performance.
查看全文   查看/发表评论  下载PDF阅读器
关闭

关于我们 | 联系我们 | 投诉建议 | 隐私保护 | 用户协议

您是第21373651位访问者    渝ICP备15012534号-2

版权所有:《包装工程》编辑部 2014 All Rights Reserved

邮编:400039 电话:023-68795652 Email: designartj@126.com

    

渝公网安备 50010702501716号